{"id":9934,"date":"2026-03-09T16:31:51","date_gmt":"2026-03-09T14:31:51","guid":{"rendered":"https:\/\/wpckraft.ro\/?p=9934"},"modified":"2026-03-16T15:03:30","modified_gmt":"2026-03-16T13:03:30","slug":"substructura-fatada-ventilata","status":"publish","type":"post","link":"https:\/\/wpckraft.ro\/en\/substructura-fatada-ventilata\/","title":{"rendered":"Support substructure for a ventilated facade: dimensions, thicknesses, and design rules"},"content":{"rendered":"<p class=\"wp-block-paragraph\">O <strong>ventilated facade<\/strong> It is a technical system consisting of several layers: a structural wall, thermal insulation, a metal substructure, and cladding material. The proper functioning of the entire system depends largely on <strong>support structure<\/strong>, the component that bears the loads and maintains the system's flatness.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In practice, the cladding material is only the visible part. The stability and durability of a ventilated facade are determined by how the substructure is designed and sized.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Modern cladding systems mounted on a framework create an air gap between the wall and the cladding, which helps protect the building and stabilize the thermal performance of the facade.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-rolul-structurii-suport-intr-un-sistem-de-fatada-ventilata\">The Role of the Support Structure in a Ventilated Facade System<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The substructure has four main roles:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. supports the weight of the system<\/strong><br><strong>2. distributes wind loads to the building structure<\/strong><br><strong>3. creates the ventilation space<\/strong><br><strong>4. ensures the facade is level<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A typical ventilated facade system may have the following weights:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Component<\/th><th>Approximate weight<\/th><\/tr><\/thead><tbody><tr><td>WPC panel<\/td><td>12\u201320 kg\/sq m<\/td><\/tr><tr><td>aluminum substructure<\/td><td>5\u201310 kg\/sq m<\/td><\/tr><tr><td>consoles + accessories<\/td><td>2\u20135 kg\/sq m<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The total weight often reaches:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>20\u201330 kg\/sq m<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the case of ceramic or fiber-cement panels, the weight may exceed:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>40\u201350 kg\/sq m<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These values determine the sizing:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>profile thicknesses<\/li>\n\n\n\n<li>the distance between the brackets<\/li>\n\n\n\n<li>the type of anchor used.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-grosimea-minima-recomandata-pentru-profilele-din-aluminiu\">Recommended minimum thickness for aluminum profiles<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In professional projects involving <strong>ventilated facade<\/strong>, the aluminum profiles must be sized to ensure sufficient rigidity for the installed panels.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In most systems used in Europe, profiles with the following thicknesses are used:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Profile Type<\/th><th>Recommended thickness<\/th><\/tr><\/thead><tbody><tr><td>secondary profile<\/td><td>2 mm<\/td><\/tr><tr><td>vertical structural profile<\/td><td>2\u20132.5 mm<\/td><\/tr><tr><td>heavy-panel systems<\/td><td>more than 2.5 mm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Thinner profiles of <strong>2 mm<\/strong> may cause over time:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>wind-induced vibrations<\/li>\n\n\n\n<li>local deformations<\/li>\n\n\n\n<li>stress in the panel fasteners.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Based on experience in construction, structural rigidity is one of the most important factors for the stability of a ventilated facade.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-distan\u021ba-corecta-intre-console-\u0219i-profile\">The correct distance between brackets and profiles<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/wpckraft.ro\/wp-content\/uploads\/2026\/03\/ChatGPT-Image-Mar-9-2026-03_49_50-PM.png\" alt=\"Distribu\u021bia \u00eenc\u0103rc\u0103rilor \u00eentr-o fatada ventilata asupra substructurii din aluminiu\" class=\"wp-image-9937\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>In a ventilated facade, the support structure must be designed to bear both the weight of the system and wind pressure.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The correct sizing of the support structure depends on the distance between the fasteners.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In most ventilated facade systems:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>distance between brackets:<\/strong><br>400\u2013600 mm<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>distance between vertical profiles:<\/strong><br>400\u2013500 mm<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In areas exposed to strong winds or near tall buildings, the distance may be reduced to:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>300\u2013400 mm<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This uniform distribution of the brackets ensures that loads are properly transferred to the structural wall.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-lungimea-consolelor-\u0219i-pozi\u021bionarea-lor\">The length of the brackets and their positioning<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Brackets are the components that connect the substructure to the building's wall.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Their length depends on:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>the thickness of the thermal insulation<\/li>\n\n\n\n<li>ventilation space<\/li>\n\n\n\n<li>the final position of the facade.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">In most ventilated systems, the cantilevers range in length from:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>80 mm and 200 mm<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Consoles are usually made of:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>extruded aluminum<\/li>\n\n\n\n<li>galvanized steel.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">They must be anchored to the building's structure using:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>mechanical dowels<\/li>\n\n\n\n<li>chemical anchors.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-dimensiunea-spa\u021biului-de-ventila\u021bie\">Size of the ventilation space<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The air space between the wall and the cladding is the element that determines the operation of a <strong>ventilated facades<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In most modern systems, the minimum recommended space is:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>20 mm<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In projects involving tall facades or large panels, the space can reach:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>30\u201340 mm<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This space allows you to:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>air circulation<\/li>\n\n\n\n<li>drainage of seepage water<\/li>\n\n\n\n<li>drying of the thermal insulation.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-toleran\u021be-admise-la-montajul-substructurii\">Permissible Tolerances for Substructure Installation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The flatness of the support structure is essential for the proper installation of the panels.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The standard tolerances are:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Element<\/th><th>Tolerance<\/th><\/tr><\/thead><tbody><tr><td>flatness of the profiles<\/td><td>\u00b12 mm \/ 2 m<\/td><\/tr><tr><td>alignment of the brackets<\/td><td>\u00b13 mm<\/td><\/tr><tr><td>the difference between profiles<\/td><td>max 2 mm<\/td><\/tr><tr><td>deviation on the facade<\/td><td>max 5 mm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Exceeding these values results in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>uneven joints<\/li>\n\n\n\n<li>panel tensioning<\/li>\n\n\n\n<li>deformations of the cladding.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-test-simplu-de-rigiditate-utilizat-in-\u0219antier\">Simple stiffness test used on a construction site<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A quick test used by many installation teams involves checking the structure's rigidity before installing the cladding.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Procedure:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>The support structure is fully assembled<\/li>\n\n\n\n<li>A lateral force is applied manually to the central area of the profile.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">If the profile shows visible deflection or vibration, the structure must be stiffened by:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>adding brackets<\/li>\n\n\n\n<li>reducing the distance between profiles<\/li>\n\n\n\n<li>the use of thicker profiles.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-cum-recuno\u0219ti-o-structura-suport-corect-executata\">How to Recognize a Properly Constructed Support Structure<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In a properly constructed ventilated facade, several distinct elements can be observed:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2714 perfectly aligned profiles<br>\u2714 Consistent spacing between elements<br>\u2714 brackets mechanically anchored to the wall<br>\u2714 Continuous ventilation space<br>\u2714 Correctly sized fasteners.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When these conditions are met, the system can operate reliably for decades.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-verificari-tehnice-recomandate-inainte-de-montajul-panourilor\">Recommended Technical Checks Before Installing the Panels<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">After the substructure has been fully assembled, but before the cladding panels are installed, it is recommended to perform a technical inspection of the support structure. At this stage, any errors can be corrected without affecting the cladding material.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Checking the flatness of the structure<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The flatness of the profiles must be checked using a laser level or a straightedge at least 2 meters long.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The recommended tolerance is:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00b12 mm over a length of 2 m<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">More significant deviations can result in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>uneven gaps between panels<\/li>\n\n\n\n<li>tightening the fasteners<\/li>\n\n\n\n<li>deformation of the cladding.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">2. Checking the rigidity of the profiles<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vertical profiles must be sufficiently rigid to withstand wind loads.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A simple test frequently used on construction sites involves applying moderate lateral pressure to the center of the profile.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A properly sized profile:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2714 shows no visible vibrations<br>\u2714 Does not become permanently deformed<br>\u2714 Returns immediately to its original position.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If the profile shows pronounced flexion, it is possible that:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>the profile thickness is insufficient<\/li>\n\n\n\n<li>the distance between the brackets is too great.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">3. Checking the anchoring of the brackets<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The brackets must be mechanically fastened to the structural wall.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Check the following:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>the type of anchors used<\/li>\n\n\n\n<li>anchor depth<\/li>\n\n\n\n<li>the correct position of the screws.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The following are commonly used for concrete or solid masonry walls:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>mechanical dowels<\/li>\n\n\n\n<li>chemical anchors.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">4. Checking the ventilation space<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The space between the wall and the cladding material must be continuous across the entire surface of the facade.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The recommended minimum value is:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>20 mm<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For tall facades or large panels, the space can be extended to:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>30\u201340 mm<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This space allows air to circulate and any moisture to escape.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-parametri-tehnici-utiliza\u021bi-frecvent-in-proiectarea-substructurii\">Technical parameters commonly used in substructure design<\/h2>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1536\" height=\"1024\" data-id=\"9936\" src=\"https:\/\/wpckraft.ro\/wp-content\/uploads\/2026\/03\/40e6febe-ef57-4f79-933e-d1b8740305fb.png\" alt=\"\" class=\"wp-image-9936\"\/><\/figure>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The diagram shows the parameters commonly used in the design of a support structure for a ventilated facade, including the thickness of the aluminum profiles, the distance between the brackets, and the minimum ventilation clearance.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In projects involving <strong>ventilated facade<\/strong>, the support structure is designed based on the cladding material, the height of the building, and wind loads.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The following parameters are frequently used in ventilated facade projects:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Element<\/th><th>Recommended value<\/th><\/tr><\/thead><tbody><tr><td>Aluminum Profile Thickness<\/td><td>minimum <strong>2\u20132.5 mm<\/strong><\/td><\/tr><tr><td>Distance between brackets<\/td><td><strong>400\u2013600 mm<\/strong><\/td><\/tr><tr><td>Distance between vertical profiles<\/td><td><strong>400\u2013500 mm<\/strong><\/td><\/tr><tr><td>Minimum ventilation clearance<\/td><td><strong>20 mm<\/strong><\/td><\/tr><tr><td>WPC System Weight<\/td><td><strong>20\u201330 kg\/sq m<\/strong><\/td><\/tr><tr><td>Structural flatness tolerance<\/td><td><strong>\u00b12 mm \/ 2 m<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">These values may vary depending on the project, but they represent the parameters commonly used to design a stable substructure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A properly sized support structure allows for the precise installation of the panels and ensures the proper operation of the ventilation system behind the cladding.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/wpckraft.ro\/en\/fatada-ventilata\/\" target=\"_blank\" rel=\"noreferrer noopener\">See compatible WPC facades<\/a><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>O fatada ventilata este un sistem tehnic compus din mai multe straturi: perete structural, termoizola\u021bie, substructur\u0103 metalic\u0103 \u0219i material de placare. Func\u021bionarea corect\u0103 a \u00eentregului ansamblu depinde \u00een mare m\u0103sur\u0103 de structura suport, elementul care preia \u00eenc\u0103rc\u0103rile \u0219i men\u021bine planeitatea sistemului. \u00cen practic\u0103, materialul de placare este doar partea vizibil\u0103. Stabilitatea \u0219i durabilitatea unei fa\u021bade [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":9935,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-9934","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.0 (Yoast SEO v26.1.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Substructura fatada ventilata: grosimi, distante si parametri tehnici<\/title>\n<meta name=\"description\" content=\"Cum se proiecteaz\u0103 corect substructura unei fa\u021bade ventilate: grosimi profile aluminiu, distan\u021be \u00eentre console \u0219i parametri tehnici.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/wpckraft.ro\/en\/substructura-fatada-ventilata\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Substructura suport pentru o fatada ventilata: dimensiuni, grosimi \u0219i reguli de proiectare\" \/>\n<meta property=\"og:description\" content=\"Cum se proiecteaz\u0103 corect substructura unei fa\u021bade ventilate: grosimi profile aluminiu, distan\u021be \u00eentre console \u0219i parametri tehnici.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/wpckraft.ro\/en\/substructura-fatada-ventilata\/\" \/>\n<meta property=\"og:site_name\" content=\"WPCraft\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/WPCKraft\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-09T14:31:51+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-16T13:03:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/wpckraft.ro\/wp-content\/uploads\/2026\/03\/parametri-structura-fatada-ventilata.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1536\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Tudor\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tudor\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/\"},\"author\":{\"name\":\"Tudor\",\"@id\":\"https:\/\/wpckraft.ro\/#\/schema\/person\/c3ee75715478444e330dc74dc835b65c\"},\"headline\":\"Substructura suport pentru o fatada ventilata: dimensiuni, grosimi \u0219i reguli de proiectare\",\"datePublished\":\"2026-03-09T14:31:51+00:00\",\"dateModified\":\"2026-03-16T13:03:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/\"},\"wordCount\":1169,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/wpckraft.ro\/#organization\"},\"image\":{\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/wpckraft.ro\/wp-content\/uploads\/2026\/03\/parametri-structura-fatada-ventilata.png\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/\",\"url\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/\",\"name\":\"Substructura fatada ventilata: grosimi, distante si parametri tehnici\",\"isPartOf\":{\"@id\":\"https:\/\/wpckraft.ro\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/wpckraft.ro\/wp-content\/uploads\/2026\/03\/parametri-structura-fatada-ventilata.png\",\"datePublished\":\"2026-03-09T14:31:51+00:00\",\"dateModified\":\"2026-03-16T13:03:30+00:00\",\"description\":\"Cum se proiecteaz\u0103 corect substructura unei fa\u021bade ventilate: grosimi profile aluminiu, distan\u021be \u00eentre console \u0219i parametri tehnici.\",\"breadcrumb\":{\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#primaryimage\",\"url\":\"https:\/\/wpckraft.ro\/wp-content\/uploads\/2026\/03\/parametri-structura-fatada-ventilata.png\",\"contentUrl\":\"https:\/\/wpckraft.ro\/wp-content\/uploads\/2026\/03\/parametri-structura-fatada-ventilata.png\",\"width\":1536,\"height\":1024,\"caption\":\"Diagrama tehnica ce arata parametrii utilizati frecvent in proiectarea substructurii pentru o fatada ventilata: grosimea profilelor, distanta dintre console si spatiul de ventilatie.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Prima pagin\u0103\",\"item\":\"https:\/\/wpckraft.ro\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Substructura suport pentru o fatada ventilata: dimensiuni, grosimi \u0219i reguli de proiectare\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/wpckraft.ro\/#website\",\"url\":\"https:\/\/wpckraft.ro\/\",\"name\":\"WPCKraft\",\"description\":\"Terase WPC \u0219i Decking WPC pentru genera\u021bii\",\"publisher\":{\"@id\":\"https:\/\/wpckraft.ro\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/wpckraft.ro\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Organization\",\"Place\",\"HomeAndConstructionBusiness\"],\"@id\":\"https:\/\/wpckraft.ro\/#organization\",\"name\":\"WpcKraft\",\"url\":\"https:\/\/wpckraft.ro\/\",\"logo\":{\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#local-main-organization-logo\"},\"image\":{\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#local-main-organization-logo\"},\"sameAs\":[\"https:\/\/www.facebook.com\/WPCKraft\",\"https:\/\/www.instagram.com\/wpc_kraft\/\"],\"address\":{\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#local-main-place-address\"},\"telephone\":[\"0787333972\"],\"openingHoursSpecification\":[{\"@type\":\"OpeningHoursSpecification\",\"dayOfWeek\":[\"Monday\",\"Tuesday\",\"Wednesday\",\"Thursday\",\"Friday\"],\"opens\":\"10:00\",\"closes\":\"19:00\"},{\"@type\":\"OpeningHoursSpecification\",\"dayOfWeek\":[\"Saturday\"],\"opens\":\"10:00\",\"closes\":\"14:00\"},{\"@type\":\"OpeningHoursSpecification\",\"dayOfWeek\":[\"Sunday\"],\"opens\":\"00:00\",\"closes\":\"00:00\"}],\"email\":\"tuleitudor@gmail.com\",\"areaServed\":\"Romania\",\"vatID\":\"RO24422266\",\"taxID\":\"RO24422266\",\"priceRange\":\"$$$\",\"currenciesAccepted\":\"Lei, Euro\",\"paymentAccepted\":\"Transfer or Cash\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/wpckraft.ro\/#\/schema\/person\/c3ee75715478444e330dc74dc835b65c\",\"name\":\"Tudor\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/wpckraft.ro\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/efe8929f744dfb55e44b2e08fa362c3c6742f3340306df3f79e9720432b24b50?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/efe8929f744dfb55e44b2e08fa362c3c6742f3340306df3f79e9720432b24b50?s=96&d=mm&r=g\",\"caption\":\"Tudor\"},\"url\":\"https:\/\/wpckraft.ro\/en\/author\/tudor\/\"},{\"@type\":\"PostalAddress\",\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#local-main-place-address\",\"streetAddress\":\"Str. Florea nr.8, Str. Moara de vant nr.10\",\"addressLocality\":\"Iasi\",\"postalCode\":\"700373\",\"addressRegion\":\"Romania\",\"addressCountry\":\"RO\"},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#local-main-organization-logo\",\"url\":\"https:\/\/wpckraft.ro\/wp-content\/uploads\/2022\/05\/228347850_109762114737624_6544222890320482222_n-removebg-preview.png\",\"contentUrl\":\"https:\/\/wpckraft.ro\/wp-content\/uploads\/2022\/05\/228347850_109762114737624_6544222890320482222_n-removebg-preview.png\",\"width\":463,\"height\":464,\"caption\":\"WpcKraft\"}]}<\/script>\n<meta name=\"geo.placename\" content=\"Iasi\" \/>\n<meta name=\"geo.region\" content=\"Romania\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Ventilated facade substructure: thicknesses, spacing, and technical parameters","description":"How to Properly Design the Substructure of a Ventilated Facade: Aluminum Profile Thicknesses, Spacing Between Brackets, and Technical Specifications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/wpckraft.ro\/en\/substructura-fatada-ventilata\/","og_locale":"en_US","og_type":"article","og_title":"Substructura suport pentru o fatada ventilata: dimensiuni, grosimi \u0219i reguli de proiectare","og_description":"Cum se proiecteaz\u0103 corect substructura unei fa\u021bade ventilate: grosimi profile aluminiu, distan\u021be \u00eentre console \u0219i parametri tehnici.","og_url":"https:\/\/wpckraft.ro\/en\/substructura-fatada-ventilata\/","og_site_name":"WPCraft","article_publisher":"https:\/\/www.facebook.com\/WPCKraft","article_published_time":"2026-03-09T14:31:51+00:00","article_modified_time":"2026-03-16T13:03:30+00:00","og_image":[{"width":1536,"height":1024,"url":"https:\/\/wpckraft.ro\/wp-content\/uploads\/2026\/03\/parametri-structura-fatada-ventilata.png","type":"image\/png"}],"author":"Tudor","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Tudor","Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#article","isPartOf":{"@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/"},"author":{"name":"Tudor","@id":"https:\/\/wpckraft.ro\/#\/schema\/person\/c3ee75715478444e330dc74dc835b65c"},"headline":"Substructura suport pentru o fatada ventilata: dimensiuni, grosimi \u0219i reguli de proiectare","datePublished":"2026-03-09T14:31:51+00:00","dateModified":"2026-03-16T13:03:30+00:00","mainEntityOfPage":{"@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/"},"wordCount":1169,"commentCount":0,"publisher":{"@id":"https:\/\/wpckraft.ro\/#organization"},"image":{"@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#primaryimage"},"thumbnailUrl":"https:\/\/wpckraft.ro\/wp-content\/uploads\/2026\/03\/parametri-structura-fatada-ventilata.png","inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/","url":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/","name":"Ventilated facade substructure: thicknesses, spacing, and technical parameters","isPartOf":{"@id":"https:\/\/wpckraft.ro\/#website"},"primaryImageOfPage":{"@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#primaryimage"},"image":{"@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#primaryimage"},"thumbnailUrl":"https:\/\/wpckraft.ro\/wp-content\/uploads\/2026\/03\/parametri-structura-fatada-ventilata.png","datePublished":"2026-03-09T14:31:51+00:00","dateModified":"2026-03-16T13:03:30+00:00","description":"How to Properly Design the Substructure of a Ventilated Facade: Aluminum Profile Thicknesses, Spacing Between Brackets, and Technical Specifications.","breadcrumb":{"@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#primaryimage","url":"https:\/\/wpckraft.ro\/wp-content\/uploads\/2026\/03\/parametri-structura-fatada-ventilata.png","contentUrl":"https:\/\/wpckraft.ro\/wp-content\/uploads\/2026\/03\/parametri-structura-fatada-ventilata.png","width":1536,"height":1024,"caption":"Diagrama tehnica ce arata parametrii utilizati frecvent in proiectarea substructurii pentru o fatada ventilata: grosimea profilelor, distanta dintre console si spatiul de ventilatie."},{"@type":"BreadcrumbList","@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Prima pagin\u0103","item":"https:\/\/wpckraft.ro\/"},{"@type":"ListItem","position":2,"name":"Substructura suport pentru o fatada ventilata: dimensiuni, grosimi \u0219i reguli de proiectare"}]},{"@type":"WebSite","@id":"https:\/\/wpckraft.ro\/#website","url":"https:\/\/wpckraft.ro\/","name":"WPCKraft","description":"WPC Patios and WPC Decking for Generations to Come","publisher":{"@id":"https:\/\/wpckraft.ro\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/wpckraft.ro\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Organization","Place","HomeAndConstructionBusiness"],"@id":"https:\/\/wpckraft.ro\/#organization","name":"WpcKraft","url":"https:\/\/wpckraft.ro\/","logo":{"@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#local-main-organization-logo"},"image":{"@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#local-main-organization-logo"},"sameAs":["https:\/\/www.facebook.com\/WPCKraft","https:\/\/www.instagram.com\/wpc_kraft\/"],"address":{"@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#local-main-place-address"},"telephone":["0787333972"],"openingHoursSpecification":[{"@type":"OpeningHoursSpecification","dayOfWeek":["Monday","Tuesday","Wednesday","Thursday","Friday"],"opens":"10:00","closes":"19:00"},{"@type":"OpeningHoursSpecification","dayOfWeek":["Saturday"],"opens":"10:00","closes":"14:00"},{"@type":"OpeningHoursSpecification","dayOfWeek":["Sunday"],"opens":"00:00","closes":"00:00"}],"email":"tuleitudor@gmail.com","areaServed":"Romania","vatID":"RO24422266","taxID":"RO24422266","priceRange":"$$$","currenciesAccepted":"Lei, Euro","paymentAccepted":"Transfer or Cash"},{"@type":"Person","@id":"https:\/\/wpckraft.ro\/#\/schema\/person\/c3ee75715478444e330dc74dc835b65c","name":"Tudor","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/wpckraft.ro\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/efe8929f744dfb55e44b2e08fa362c3c6742f3340306df3f79e9720432b24b50?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/efe8929f744dfb55e44b2e08fa362c3c6742f3340306df3f79e9720432b24b50?s=96&d=mm&r=g","caption":"Tudor"},"url":"https:\/\/wpckraft.ro\/en\/author\/tudor\/"},{"@type":"PostalAddress","@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#local-main-place-address","streetAddress":"Str. Florea nr.8, Str. Moara de vant nr.10","addressLocality":"Iasi","postalCode":"700373","addressRegion":"Romania","addressCountry":"RO"},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/wpckraft.ro\/substructura-fatada-ventilata\/#local-main-organization-logo","url":"https:\/\/wpckraft.ro\/wp-content\/uploads\/2022\/05\/228347850_109762114737624_6544222890320482222_n-removebg-preview.png","contentUrl":"https:\/\/wpckraft.ro\/wp-content\/uploads\/2022\/05\/228347850_109762114737624_6544222890320482222_n-removebg-preview.png","width":463,"height":464,"caption":"WpcKraft"}]},"geo.placename":"Iasi","geo.region":"Romania"},"_links":{"self":[{"href":"https:\/\/wpckraft.ro\/en\/wp-json\/wp\/v2\/posts\/9934","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wpckraft.ro\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wpckraft.ro\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wpckraft.ro\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/wpckraft.ro\/en\/wp-json\/wp\/v2\/comments?post=9934"}],"version-history":[{"count":2,"href":"https:\/\/wpckraft.ro\/en\/wp-json\/wp\/v2\/posts\/9934\/revisions"}],"predecessor-version":[{"id":9956,"href":"https:\/\/wpckraft.ro\/en\/wp-json\/wp\/v2\/posts\/9934\/revisions\/9956"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wpckraft.ro\/en\/wp-json\/wp\/v2\/media\/9935"}],"wp:attachment":[{"href":"https:\/\/wpckraft.ro\/en\/wp-json\/wp\/v2\/media?parent=9934"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wpckraft.ro\/en\/wp-json\/wp\/v2\/categories?post=9934"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wpckraft.ro\/en\/wp-json\/wp\/v2\/tags?post=9934"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}